How can we determine whether the membrane switch panel is qualified after the temperature resistance test?
After the temperature resistance test is completed, one cannot simply rely on intuition for judgment. Instead, a strict quantitative assessment must be conducted based on the four dimensions of "appearance, function, structure, and physical properties".
Taking into account industry standards (such as GB/T 2423, IEC 60068) and the actual requirements of automotive/industrial-grade panels, I have compiled a detailed list of qualified judgment criteria for you:

Dimension 1: Visual Inspection (Most Intuitive)
This is the first step. It is usually conducted through visual inspection or microscopic observation 2 to 4 hours after the system has been restored at normal temperature.
| Inspection items | Passing criteria | Defective phenomena |
| Surface condition | Flat and smooth, without any changes | Bubble formation, delamination, warping, deformation (these are the most common failures) |
| Color/Glazing | Consistent with before testing, color difference ΔE < 1.0 | Yellowing, fading, darkening, or significant decrease in surface glossiness |
| Screen printing/characters | Clear and complete, sharp edges | Blurry, broken characters, ink peeling off, and jagged edges of the characters |
| Cracks | No cracks at all | Minor cracks (silver lines) at the edges or stress points |
Dimension 2: Electrical Function (Most Core)
Just because the appearance is fine doesn't mean the internal circuitry is intact. A multimeter or specialized testing fixtures must be used for inspection.
1、Loop Resistance:
Standard: Usually, it is required to be ≤ 100Ω (refer to the design drawings for specific values).
Judgment: The increase in resistance value after testing should not exceed 20%-30% of the initial value. If the resistance is infinitely large, it indicates that the circuit is broken (open circuit).
2、Insulation resistance:
Standard: Usually requires ≥ 100 MΩ (at 500V DC).
Judgment: Prevents short circuits between lines. Decrease in insulation performance after high temperature and high humidity is a common failure.
3、Key function:
Judgment: Each key must be able to trigger normally, without consecutive presses (pressing twice gives two characters), dead keys (no response after pressing), or accidental touches.
Dimension 3: Structure and Feel (Most Easily Ignored)
The structure specific to the film panel is evaluated.
1、Adhesion test (3M tape method):
Procedure: Draw a grid on the silk-screened or inked surface of the tested panel, then stick a 3M 600/610 tape on it and quickly pull it off.
Judgment: If the ink does not fall off, it is considered qualified (usually requiring a 5B grade). High temperatures often damage the adhesion between the ink and the substrate.
2. Button Feel (Force Test):
Operation: Use a push-pull force gauge to test the pressing force of the buttons.
Judgment: The feel force should be within the standard range (such as 170-397g). If the high temperature causes the silicone or spring clips to age, the feel will become soft (collapse) and unable to rebound.
3. Bulge/Window Deformation:
Judgment: The embossed areas should not have permanent collapse or irrecoverable deformation.
Dimension 4: Material Properties (Laboratory Level)
If conducting material validation (during the research and development stage), the following data also need to be considered:
Retention rate of tensile strength: The retention rate of the tensile strength of the material after testing should be ≥ 80%.
Break elongation rate: The material should not become brittle, and the retention rate of break elongation should be ≥ 70%.
Yellowing index: The change in the yellowing index of transparent PC/PET materials after high temperature should be within the allowable range.
Summary: Recommended Judgment Process
In actual operation, it is recommended to follow the following "three-step" process for judgment:
Hot-state observation (optional): If the operation can be performed in a high-temperature chamber, observe whether the panel has blistered or deformed under high temperature (many defects will recover after cooling, and hot-state observation is the most accurate).
Cold-state recovery: Remove and place it in standard atmospheric pressure (23°C, 50% RH) for 2-4 hours (some standards require 24 hours) to eliminate thermal stress.
Comprehensive inspection:
First, check: Are there any blisters or color changes?
Then, test: Are the on/off and resistance normal?
Finally, pull: Test the tape to see if the ink has peeled off?