    Featured News

    How to determine the quality of a membrane switch after the lifespan test?

    2026-06-29

    The determination of the life test of membrane switches needs to be comprehensively evaluated from four dimensions: electrical performance, mechanical performance, appearance quality and functional reliability. If any one of them fails to meet the standards, it will be judged as unqualified. The detailed determination criteria are as follows: 

    machinery equipment (6).jpg
    Electrical performance evaluation
    This is the most crucial evaluation criterion, directly determining whether the button can conduct signals normally:

    Test item   Criteria Test method
    Contact resistance  Change rate ≤ 20% - 30% of the initial value, and absolute value ≤ 150Ω  Four-wire Kelvin method measurement
    Insulation resistance ≥ 100 MΩ (100 VDC, for 60 seconds)  High resistance meter measurement
    Base material withstand voltage  2 kVDC, no breakdown or arcing for 60 seconds  Withstand voltage tester
    Loop resistance Meets the design value (50Ω/150Ω/350Ω three levels) Multimeter/Milli-ohmmeter

    If the contact resistance changes by more than 30% or there is an open circuit (break), it is directly judged as failure.

    Mechanical performance evaluation

    Test item  Evaluation criteria Explanation
    Operating force  Within ±20% of the initial value  Measured by force sensor
    Rebound time   ≤ 6ms  Captured by oscilloscope
    Closing displacement Touch-sensitive type: 0.4 - 1.0mm, non-touch-sensitive type: 0.1 - 0.4mm Measured by displacement sensor
    Bounce ratio > 50%   Measured by oscilloscope for on-off waveform
    Feel  No sticking, no dead keys, no collapse Human pressing experience

    If the operational force variation exceeds ±20%, it indicates fatigue of the projectile or structural deformation, and it is classified as unqualified. 
    Appearance quality assessment
    After the lifespan test, the following appearance defects need to be checked item by item:
    Layering/Bubbling: There should be no layering or bubbling between each layer
    Cracking/Fracture: The panel and silver paste circuits should have no cracks or fractures
    Curling edges/delamination: The edges must not curl up and the adhesive backing must not fall off
    Text/Pattern wear: The screen printing should not be severely worn or inked off (allowable slight wear but not affecting recognition)
    Silver paste oxidation: The surface of the silver paste circuits should not show oxidation and blackening

    If there is any layering, cracking or silver paste detachment, it will be directly classified as unqualified. 

    Function reliability assessment

    Assessment items  Qualification criteria
    Key press conduction Each key press should be able to conduct normally without any missed triggering
    Key release disconnection  It should be able to disconnect normally after release, without sticking or continuous conduction
    False triggering  No interference should occur when adjacent keys are pressed
    Backlight function (if any)  The LED should be normally lit, without dead lights, and the brightness attenuation should be ≤ 15% - 20% 

    If any key fails to trigger properly, gets stuck or triggers incorrectly, it will be judged as unqualified.

    Judgment process
    After the lifespan test is completed (e.g. 1 million cycles)
    ↓
    【Step 1】Overall appearance inspection
    ├─ Layering/Bubbling? → Unqualified
    ├─ Cracking/Breaking? → Unqualified
    └─ Severe wear? → Unqualified
    ↓
    【Step 2】Electrical performance test
    ├─ Change in contact resistance > 30%? → Unqualified
    ├─ Insulation resistance < 100 MΩ? → Unqualified
    └─ Open circuit/short circuit? → Unqualified
    ↓
    【Step 3】Mechanical performance test
    ├─ Change in operating force > ±20%? → Unqualified
    ├─ Rebound time > 6 ms? → Unqualified
    └─ Stalling/Stuck keys? → Unqualified
    ↓
    【Step 4】Function verification
    ├─ Leakage trigger/Sticking? → Unqualified
    └─ Incorrect trigger? → Unqualified
    ↓
    All passed → Judged as qualified

    Differentiation standards in various application fields 
    The strictness of the criteria varies across different industries:

    Application field   Lifespan requirement Contact resistance change  Special requirements
    Consumer electronics  ≥100,000 times ≤30% Appearance wear can be moderately relaxed
    Industrial control ≥1,000,000 times  ≤20%   Needs to pass temperature cycling from -40℃ to 85℃
    Medical equipment ≥5,000,000 times ≤15%  Needs to withstand disinfectant wiping and biocompatibility
    Automotive electronics  ≥10,000,000 times ≤15% Needs to pass 100G impact and salt spray for 48 hours

    Common Failure Modes and Causes Analysis

    Failure Phenomenon Possible Causes Improvement Direction
    Contact Resistance Soars  Silver Paste Wear and Oxidation  Thicken Silver Paste Layer, Add Protective Ink
    Insulation Resistance Decreases  Moisture Infiltration, Silver Migration Strengthen Sealing, Use Carbon Ink Mixture Scheme
    Button Adhesion Spring Fatigue, Isolation Layer Deformation Replace Spring Material, Thicken Isolation Layer
    Panel Cracking  Insufficient Thickness of Base Material, Concentrated Pressing Stress Thicken Panel, Optimize Button Layout
    Layer Separation and Bubbling Aging of Adhesive Layer, Inadequate Curing Increase Bonding Pressure, Optimize Curing Process

    Summary: The determination of the lifespan test of membrane switches follows the "one-vote veto" principle - if any of the four major categories of indicators - appearance, electrical, mechanical, and functional - fails to meet the standards, it is judged as unqualified. The core indicators are that the contact resistance change is ≤ 20% - 30%, the insulation resistance is ≥ 100 MΩ, the operation force change is ≤ ± 20%, and there is no trigger leakage or adhesion. The standards vary greatly in different application fields. For industrial use, the requirement is 1 million cycles, for medical use, it is 5 million cycles, and for automotive use, it is 10 million cycles. When selecting, the determination threshold should be determined based on the actual application scenario.