    How to distinguish the COM terminal and the trigger terminal of the membrane switch wiring?

    2026-06-23

    Distinguishing between the COM terminal (common terminal) and the trigger terminal of the membrane switch wiring is a fundamental operation in wiring and maintenance. Here are several practical methods for this distinction:

    主图-4.jpg

    Understanding the circuit structure of the membrane switch
    The circuit of the membrane switch usually adopts two methods: matrix arrangement (row lines + column lines) or independent output.

    Matrix type: Multiple keys share the row lines and column lines. The row lines are usually used as common terminals (COM), while the column lines serve as trigger lines (signal lines).
    Independent output type: Each key has its own COM line and trigger line. This is commonly used in scenarios with a small number of keys.

    Multimeter continuity test method (most commonly used)
    This is the most accurate and reliable method for distinction, and it can be operated with just one multimeter:

    Operation steps
    1. Multimeter settings: Set the multimeter to the buzzer mode (on-off mode) or the resistance mode (R×10).
    2. Determine the reference line: Select any one of the rows as the reference and fix one of the probes to this line.
    3. Test one by one: Use the other probe to touch each of the remaining rows one by one and record which lines can conduct.
    4. Press the buttons: Press each button one by one and observe which two lines conduct when the button is pressed and are disconnected when it is released.
    5. Judgment rules:
    COM terminal characteristics: Forms an on-off relationship with multiple trigger terminals. For example, one COM line may correspond to 3 to 5 trigger terminals (corresponding to multiple buttons).
    Trigger terminal characteristics: Usually only forms an on-off relationship with one COM line and conducts only when a specific button is pressed.

    Judgment Rule
    "A wire that is connected to multiple others is a COM (common terminal), a wire that is only connected to one other wire is a trigger terminal; a wire that does not conduct when not pressed but conducts when pressed is in a normal state."

    Observation method based on the arrangement pattern of leads
    If the leads of the membrane switch have clear silk-screen markings or an arrangement pattern, the appearance can be directly used for judgment:
    Alternating arrangement: Many membrane switches adopt an alternating arrangement pattern of "COM-trigger-COM-trigger", with the COM lines usually located at odd-numbered positions (the 1st, 3rd, 5th... wires), and the trigger ends located at even-numbered positions.
    Grouped arrangement: The COM lines are concentrated on one side (such as the first 1-2 wires of the lead), and the trigger ends are concentrated on the other side.
    Silk-screen markings: Some membrane switches have silk-screened markings at the end of the leads or on the back of the panel, such as "C", "COM", "GND", etc., which correspond to the common terminals.

    Circuit principle inference method
    Based on the circuit design principle of the membrane switch, logical inferences are made:
    The number of COM lines is small and the number of trigger lines is large: In matrix design, the number of COM lines (row lines) is usually much less than the number of trigger lines (column lines). For example, a 16-key keyboard may have only 4 row lines (COM) and 4 column lines (trigger), or 8 row lines + 8 column lines.
    The COM line has a thicker line width: Since the COM line carries the common current of multiple keys, the line width is usually thicker than the trigger line when designing to reduce resistance and voltage drop.
    Identification of the grounding terminal: If the membrane switch has a clear grounding mark (GND), then GND is usually the reference potential of the COM terminal.

    Power-on Testing Method (Proceed with caution)
    Under the premise of ensuring safety, the following can be verified through power-on testing:
    1. Series Indicator Light: Connect an LED indicator light and a current-limiting resistor (such as 330Ω) in series between the suspected COM terminal and the trigger terminal.
    2. Press Test: Press the corresponding button. If the LED lights up, it indicates that these two wires are the COM and trigger terminals respectively.
    3. Polarity Verification: Swap the positions of the two wires. If the LED still lights up, it means the judgment is correct (it's just the direction of the LED reversed); if it doesn't light up, it indicates that at least one of the wires has been judged incorrectly.

    Common wiring definition example
    Take a 16-key membrane switch with 8 output lines as an example:

    Wiring sequence number  1 2 3 4 5 6 7 8
    Function COM1 TRIG1 COM2 TRIG2 COM3 TRIG3 COM4 TRIG4
    Explanation Row line 1  Column line 1 Row line 2 Column line 2 Row line 3 Column line 3 Row line 4 Column line 4

    Button triggering relationship: Pressing the button at the 1st row and 1st column → COM1 and TRIG1 are connected; pressing the button at the 2nd row and 3rd column → COM2 and TRIG3 are connected, and so on. 

    💡  Summary: The most recommended method is to use the continuity test of the multimeter. It is simple to operate and provides accurate results. The core judgment logic is: The COM terminal can form a continuity relationship with multiple trigger terminals, while the trigger terminals are usually paired with only one COM wire. When testing, make sure to turn off the power supply to avoid damaging the multimeter or the switch circuit. If the wiring has a printed label, refer to the label first; if there is no label, establish a complete continuity relationship table by testing each wire one by one, so as to accurately distinguish the functions of all pins.