    How to test the adhesion and conductivity after curing?

    2026-06-15

    The performance verification of the conductive pastes (such as silver paste and carbon paste) for the solidified membrane switches is a crucial step in ensuring product quality. For the tests of adhesion and conductivity, the industrial sector and laboratories have a set of standardized testing methods. The following is the specific testing plan:

    15年丰富的薄膜开关自主研发设计经验-2.png

    I. Adhesion Testing Method
    The adhesion test is used to evaluate the firmness of the bond between the coating and the substrate. Common testing methods include the following:
    1. Grid Test (Grid Test)
    Application scenario: The most basic and widely used qualitative/semi-quantitative test, suitable for rapid on-site inspection.
    Operation method: Use a grid cutter with a specific blade spacing (usually 1mm or 2mm) to make two sets of perpendicular parallel lines on the coating surface, forming a grid-like cut. The cutting depth must penetrate the coating to the base material surface. After cleaning the debris, attach a pressure-sensitive tape and rub it firmly to ensure complete contact. Finally, quickly peel off the tape at an angle of approximately 60 degrees or vertically within a very short time (less than 1 second).
    Judgment criteria: Evaluate the grade based on the proportion of the area where the coating peels off (0 level to 5 levels). 0 level represents that the edge of the cut is completely smooth without peeling (best), and 5 level represents that the peeling area is greater than 65% (worst).

    2. Pulling Method
    Applicable scenarios: Used for quantitative testing in high-end fields such as automobiles and aviation, with objective and accurate data.
    Operation method: Use a tensile testing machine or a portable tester. Attach the special metal test column to the coating surface with high-strength glue. After curing, cut through the coating along the outer edge of the test column to the substrate. Then, apply vertical tension at a constant rate until the coating separates from the substrate.
    Judgment criteria: Record the maximum tensile force value (MPa) at the time of failure, and observe the position of the failure interface. If the failure occurs inside the plastic substrate (such as the plastic body tearing), it indicates that the adhesion of the coating has exceeded the strength of the substrate itself, which is an excellent performance.

    3. Cross-cutting Method (X-shaped cutting)
    Applicable scenarios: Suitable for situations where the coating is thick or the sample shape is not suitable for grid cutting.
    Operation method: Use a single-edge cutting tool to make an "X" shape cut with an angle of 30° to 45° on the coating. Stick a pressure-sensitive tape and remove it within 5 minutes. Observe the peeling of the cut edge to evaluate the adhesion.

    II. Conductivity Testing Method
    The determination of conductivity involves static resistance measurement and environmental reliability verification. It mainly relies on the following technologies:

    1. Four-probe method (the most precise and widely used)
    Principle and operation: Four probes are placed at equal intervals on the sample surface. The two outer probes are supplied with a constant current, while the two inner probes measure the voltage drop. Due to the extremely high input impedance at the voltage measurement end, this method effectively eliminates the interference of the contact resistance between the probe and the sample on the results.
    Application scope: Particularly suitable for the measurement of sheet resistance or volume resistivity of thin films, conductive coatings, semiconductor materials, etc., with extremely high accuracy.

    2. Two-probe method / Microohmmeter method
    Operation method: Apply probes at the designated distance on the strip or use a microohmmeter for measurement. Convert the measured volume resistivity based on the width, length, and thickness of the sample.
    Precautions: This method is greatly affected by contact resistance. Ensure that the electrodes are in close contact with the sample surface and are clean and flat. In case of necessity, use conductive silver glue to improve the contact condition.

    3. Verification of Conductivity after Environmental Reliability
    In the practical application of film switches, in addition to testing the initial conductivity, it is also necessary to simulate harsh environments to examine their stability:
    Testing after high-temperature and high-humidity/salt fog aging: Place the sample in a humid and salt fog environment for an aging test, and then measure the change rate of the contact resistance or sheet resistance again. This can effectively test whether the coating has been damaged due to water vapor infiltration or oxidation of the conductive network.

    Summary of recommendations: On the film switch production line, it is recommended to use the "grid method" for rapid adhesion inspection and the "four-probe instrument" for precise measurement of the conductive resistance. During the research and development or customer complaint analysis stage, the "pulling method" can be introduced to obtain quantitative mechanical data, and combined with environmental aging tests, the long-term reliability of the material can be comprehensively evaluated.