    How to test the waterproof and oil-proof performance of a membrane button panel?

    2026-05-19

    To test the waterproof and oil-resistant properties of the membrane button panels, it is usually divided into two types of tests: the finished product protection level test (for the entire device) and the material surface performance test (for the film material itself).
    Based on your previous questions, I have compiled a complete testing scheme from "professional laboratories" to "simple self-tests":
    Waterproof performance test
    The waterproof test mainly verifies the sealing performance of the panel and the anti-permeation ability of the film material under pressure.

    productive process (9).jpg

    1. Product protection level testing (IP rating)
    This is the most standard industrial testing method, based on GB/T 4208 or IEC 60529 standards.


    IPX5/IPX6 (Waterproof test):
    Simulation scenario: Simulate heavy rain erosion or equipment cleaning.
    Method: Use a standard nozzle (inner diameter 6.3mm or 12.5mm), at a distance of 2.5-3 meters from the panel, spray in all directions at a specific flow rate (12.5L/min or 100L/min) for 3 minutes.
    Judgment: There are no water ingress marks inside the panel (especially on the circuit and backlight areas), and the function is normal.

    IPX7 (Resistant to Short-term Immersion):
    Simulation scenario: Accidental immersion in water or short-term exposure.
    Method: Completely immerse the panel in water that is 1 meter deep and keep it for 30 minutes.
    Judgment: After removal, check that there are no water droplets or water mist inside.

    2. Material-level "True Water Test"
    If your panel uses a waterproof breathable membrane (ePTFE membrane), merely conducting an airtightness test is insufficient, as the permeation behavior of water molecules and gas molecules is different.
    True Water Testing Method:
    Principle: Use water as the medium and apply pressure (such as 10kPa - 100kPa) to the membrane to simulate the actual water pressure.
    Advantages: Can detect micro-pore leakage or interface capillary phenomena that cannot be detected by gas tests.
    Simple Compression Method (DIY):
    Make a hole on the bottle cap, apply the membrane, fill with water, invert and squeeze forcefully (simulating a 0.1kg pressure), and keep for 30 minutes without leakage. This can roughly simulate the IP67 effect.

    Oil resistance performance test
    The oil resistance test is mainly conducted for kitchen appliances and industrial oil-contaminated environments to verify whether the surface coating or material of the panel can resist the penetration and adhesion of oil.
    1. Surface oil resistance test (simulating actual use)
    This is the most intuitive test, based on GB/T 4208 (enclosure protection) or food packaging-related standards.
    Application method:
    Material: Use simulated oil stains (such as vegetable oil, mineral oil or dedicated test solution).
    Operation: Drop or apply the oil stain on the panel surface and leave it for 15-30 minutes (or even longer, such as 24 hours).
    Judgment: Observe whether the oil stain penetrates through the film and enters the interior, or if there is any residue or discoloration after wiping.

    Spray test (for kitchen appliances):
    Procedure: Place the panel in the test chamber and use the spray device to spray simulated kitchen grease. The spray pressure should be controlled at 0.1 - 0.3 MPa and the process should last for 15 - 60 minutes.
    Judgment: After the test, check if the electrical performance has been affected (whether the grease has penetrated the circuit) and if the surface is easy to clean.

    2. Material-level Oil Resistance Testing (Laboratory Use)
    If you need to quantify the oil resistance of the film material itself (such as when choosing an oil-resistant coating), you can use the following standard method:


    KIT Value Test (TAPPI T 507 / ASTM D722):
    Principle: Use 12 different test solutions with varying surface tensions (numbers 1-12).
    Operation: Apply the test solution to the film surface and observe if it wets.
    Judgment: The highest numbered that the film can resist is the KIT value. The higher the KIT value (such as KIT 7 or above), the better the oil resistance, suitable for environments with high oil content such as hamburgers and fried foods.

    Contact angle test:
    Principle: Measures the contact angle of oil droplets on the film surface.
    Judgment: The larger the contact angle (greater than 90°), the better the oil repellency is, and the less likely the oil stains are to adhere.

    Summary: How to select the testing method? 

    Test purpose Recommended method Applicable scenarios
    Verify the overall waterproof performance IPX5/IPX7 rain and water immersion test     Product acceptance for household appliances, outdoor equipment, and medical devices
    Verify the quality of the breathable membrane True water pressure test At the research and development stage, verify the microscopic waterproofing ability of the ePTFE membrane sheet
    Verify the anti-oil property of kitchen panels Oil spray/moisture application test   Microwave oven, oven, and range hood panels
    Selecting anti-oil materials  KIT value test  When purchasing film raw materials or anti-oil coatings

    Safety tip: For membrane button panel, preventing oil contamination is often more challenging than preventing water contamination. Oil stains have greater permeability and adhesion, and are prone to corroding the silver paste circuits. It is recommended to clearly specify in the drawings: "The surface should be treated with an oil-resistant coating, and pass the XX-hour oil resistance test without any residue after wiping."