Mechanical Properties
The following tables present the standard mechanical property ranges for silicone rubber compounds used in keypad manufacturing. Values are representative of properly compounded and cured material tested at 23°C per the referenced ASTM methods. Actual values depend on specific compound formulation, filler system, and cure chemistry.
Hardness and Strength Properties
| Property |
Test Method |
GP Peroxide (40 A) |
GP Peroxide (60 A) |
GP Peroxide (70 A) |
Premium Pt-Cured (50 A) |
Premium Pt-Cured (60 A) |
Premium Pt-Cured (70 A) |
| Shore A Hardness |
ASTM D2240 |
40 ±5 |
60 ±5 |
70 ±5 |
50 ±5 |
60 ±5 |
70 ±5 |
| Tensile Strength (MPa) |
ASTM D412 |
6.0–8.0 |
7.5–9.5 |
8.0–10.0 |
8.0–10.5 |
9.0–11.5 |
9.5–12.0 |
| Elongation at Break (%) |
ASTM D412 |
500–700 |
350–550 |
250–400 |
450–650 |
350–500 |
250–400 |
| 100% Modulus (MPa) |
ASTM D412 |
0.4–0.8 |
1.2–1.8 |
2.0–3.0 |
0.6–1.0 |
1.5–2.2 |
2.5–3.5 |
| Tear Strength, Die B (kN/m) |
ASTM D624 |
15–25 |
20–30 |
25–35 |
25–35 |
30–40 |
35–45 |
| Compression Set, 22h @ 175°C (%) |
ASTM D395 B |
25–35 |
22–30 |
20–28 |
8–15 |
7–13 |
6–12 |
| Bashore Resilience (%) |
ASTM D2632 |
45–55 |
40–50 |
35–45 |
50–60 |
45–55 |
40–50 |
| Specific Gravity (g/cm³) |
ASTM D792 |
1.10–1.18 |
1.14–1.22 |
1.18–1.28 |
1.10–1.18 |
1.14–1.22 |
1.18–1.28 |
Note: GP = General Purpose. Values shown are typical ranges for commercial silicone compounds. For critical applications, request a Certificate of Analysis (CoA) for the specific production batch.
Industry Standards Quick Reference
| Standard |
Title / Scope |
| IEC 60529 |
Degrees of protection provided by enclosures (IP Code) |
| IEC 60068 |
Environmental testing procedures (temperature, humidity, vibration, shock, salt spray) |
| IEC 60664 |
Insulation coordination for equipment (creepage and clearance distances) |
| IEC 61000-4-2 |
Electromagnetic compatibility — Electrostatic discharge immunity test |
| ISO 10993 |
Biological evaluation of medical devices (biocompatibility) |
| ISO 13485 |
Medical devices — Quality management systems |
| IATF 16949 |
Automotive quality management system standard |
| IPC-A-610 |
Acceptability of electronic assemblies (PCB quality) |
| IPC-4552 |
Specification for electroless nickel/immersion gold (ENIG) plating |
| UL 94 |
Standard for flammability of plastic materials |
| ASTM D2240 |
Standard test method for rubber property — Durometer hardness |
| ASTM D412 |
Standard test methods for vulcanized rubber — Tension |
| ASTM D624 |
Standard test method for tear strength of conventional vulcanized rubber |
| ASTM D395 |
Standard test methods for rubber property — Compression set |
| ASTM D471 |
Standard test method for rubber property — Effect of liquids |
| RoHS 2011/65/EU |
Restriction of hazardous substances in electrical and electronic equipment |
| REACH (EC) 1907/2006 |
Registration, evaluation, authorization, and restriction of chemicals |
Frequently Ask Questions (FAQ):
Q1:What is a Silicone Rubber Keypad?
A:A Silicone Rubber Keypad is a user input device made from compression-molded silicone rubber with integrated conductive contacts. It typically features an array of molded keys that, when pressed, collapse and make electrical contact with a PCB via conductive carbon pills or gold-plated contacts on the underside of each key. Silicone Rubber Keypads are valued for their durability, environmental resistance, and comfortable tactile response.
Q2:What are the advantages of Silicone Rubber Keypads over Membrane Keypads?
A:Silicone Rubber Keypads offer: superior tactile feel with deeper key travel (typically 1-3mm vs. 0.1-0.5mm for membrane), better resistance to extreme temperatures (-40°C to +85°C vs. -20°C to +70°C), greater chemical and UV resistance for outdoor use, and more comfortable long-term use. Membrane Keypads, however, are thinner and more cost-effective in high volumes. The choice depends on the specific application requirements for environmental exposure, user comfort, and profile constraints.
Q3:What applications are Silicone Rubber Keypads used for?
A:Silicone Rubber Keypads are used in remote controls (TV, set-top box, industrial), handheld test and measurement instruments, medical handheld devices, automotive key fobs, marine electronics, outdoor communication devices, industrial controllers, and consumer electronics. They are particularly suited for applications where the device may be exposed to weather, moisture, or frequent handling.
Q4:What conductive contact options are available for Silicone Rubber Keypads?
A:Two main options are available: Carbon Pill contacts (conductive carbon-impregnated silicone pills molded into the key underside) are cost-effective, reliable, and suitable for most applications; Gold-Plated contacts (metal discs or pills with gold plating) offer lower contact resistance, excellent for low-current circuits, and preferred for high-reliability applications. The choice depends on the PCB contact design and the required electrical performance.
Q5:What is the typical operating temperature range for Silicone Rubber Keypads?
A:Standard Silicone Rubber Keypads operate reliably from -40°C to +85°C. Specialized high-temperature silicone formulations can extend this range to -60°C to +200°C for extreme applications. This wide range makes them ideal for outdoor equipment in arctic or desert environments, as well as industrial machinery near heat sources.
Q6:What is the typical lifespan of a Silicone Rubber Keypad?
A:The typical lifespan of a quality Silicone Rubber Keypad ranges from 500,000 to over 5 million cycles per key, depending on the silicone formulation, key design (web thickness and travel), and conductive contact type. Carbon pill keypads generally achieve 1-3 million cycles, while gold-plated contact keypads can exceed 5 million cycles with proper PCB gold pad specifications.