The faults that are prone to occur in the actual use of membrane switches mainly fall into three categories: electrical failure, mechanical abnormalities, and appearance degradation. The specific manifestations, causes, and troubleshooting ideas of each type of fault are as follows:

The buttons do not respond.
This is the most common fault and can be divided into two situations:
All buttons fail: Usually, there is a problem with the common part of the circuit. Possible causes include loose or oxidized connector pins (Tail) of the wiring, breakage of the wiring due to repeated bending at the root of the wiring, and the motherboard not providing the correct working voltage. When troubleshooting, first check if the connector is firmly inserted, and measure the power supply voltage and wiring continuity of the motherboard with a multimeter.
Individual button failure: Mostly a local contact problem. Common causes include dirt or oxidation on the contact surface, micro-cracks and short circuits in the silver paste lines corresponding to the button, and failure of the metal spring. Use the continuity setting of the multimeter to test each button pin one by one to locate the fault point.
Slow button response / Requires strong pressing
This is manifested as a decrease in button sensitivity, requiring a greater force than normal to trigger. The main causes include:
Contact oxidation: An oxide layer forms on the surface of the spring (visible as small black dots), causing an increase in contact resistance and making it impossible to conduct even with a gentle press.
Spring aging: After long-term use, the metal spring experiences metal fatigue, resulting in reduced elasticity and insufficient preload force.
Contact wear: The carbon beads or silver paste contacts wear out due to long-term friction, becoming thinner and reducing the contact area.
Button sticking (continues to conduct even after release)
This is manifested as no rebound after pressing, and the signal continues to be output, commonly known as "long conductance". Possible causes:
Spring collapse: The spring is overly pressed and "stuck", losing its rebound ability.
Internal contamination: Dust, oil, and other foreign substances enter the contact area, causing the contacts to stick together.
Failure of isolation layer: The isolation layer (Spacer) is damaged or deformed, preventing the upper and lower circuits from separating normally.
Ghosting/Key Jamming (False Trigger)
This manifests as pressing one key but accidentally triggering the signal of another key. This is a typical fault in matrix circuits:
Silver ion migration: In humid environments, silver ions migrate between adjacent lines to form a conductive bridge, which is the main cause.
Improper circuit layout: Long parallel lines with too close spacing are prone to leakage current.
Internal moisture: Poor interlayer sealing allows moisture to enter, causing the insulation resistance to drop sharply.
Breakage of the wiring
This manifests as a sudden failure of all keys in a certain row or the entire panel, but the switch body remains intact.
This is one of the "fatal flaws" of membrane switches:
Causes: During assembly, the root of the wiring was bent at a right angle, the wiring was designed too short and was in a tense state, and no PET reinforcement treatment was carried out.
Inspection: Focus on checking the root of the wiring and the connector interface. Use a magnifying glass to observe if there are any micro cracks.
Surface bulging / delamination
It is manifested as bubbles, bulges or separation between layers on the panel surface:
Causes: Incompatibility of adhesive and substrate, improper pressure or temperature during lamination, degradation of adhesive performance in high-temperature and high-humidity environments, improper storage conditions, etc. - Effects: Not only affects the appearance, but also causes abnormal button touch sensation and poor electrical contact.
Screen printing detachment/ fading
This is manifested as blurred button labels, pattern detachment or surface color change:
Causes: Insufficient ink adhesion (surface tension of the substrate is lower than 38 dynes/cm), no hardening treatment, long-term exposure to ultraviolet rays or chemical solvents.
Quick troubleshooting suggestions: When encountering a problem with the membrane switch, it is recommended to follow the sequence of "first the outside then the inside, first the simple then the complex" for troubleshooting - first check if the connector is loose, then use a multimeter to test for continuity to locate the faulty area, and finally consider disassembling for cleaning or replacement. If the switch still fails after cleaning, or if it has physical damages such as creases or delamination, it is recommended to replace it directly. Attempting to repair it forcefully may cause secondary risks such as short circuits.