Welcome to LuphiTouch®!
Today is 2026.11.05 , Thursday
Leave Your Message
News Categories
    Featured News

    What are the key points of the waterproof structure design for membrane switches?

    2026-05-22

    For the waterproof structure design of the membrane switch, the key design points need to be systematically considered from three aspects: structure, materials, and processes, in order to ensure the long-term reliability of the product in harsh environments.
    The core design points are as follows:

    6 (6).JPG

    1. Edge Sealing: The First Line of Defense
    This is the most critical part for waterproofing, as water is most likely to seep in through the gap between the edge of the switch and the installation panel.
    Adhesive Edge Width:
    IP65: At least 2mm continuous adhesive edge.
    IP67/IP68: 3-5mm adhesive edge, and a double-sealing design (i.e., two layers of adhesive edges inside and outside).
    Adhesive Selection:
    3M VHB (Polyurethane Foam Tape): Suitable for IP65/IP66, capable of adapting to irregular surfaces, with a peel strength > 1000 grams per inch.
    3M 300LSE (High Adhesive Polyurethane): Excellent adhesion to low surface energy plastics (such as PC, ABS).
    Silicone Sealing Ring: Suitable for IP68 applications, maintaining sealing under thermal cycling.
    Key Details: There must be no gaps or interruptions in the sealing path, and the adhesive edge must form a complete closed loop.

    2. Sealing at the outlet (tail end): The weakest link
    90% of the waterproof failure occurs at the outlet of the wiring. This is the most critical aspect of the design.
    Injection molding: Conduct a secondary injection molding at the outlet of the wiring, using plastic (such as PP, PA) to encapsulate the wiring and form an integrated seal. This is the most reliable method and is suitable for IP67/IP68.
    Gluing treatment: Apply modified silicone sealant or epoxy resin at the outlet of the wiring to fill the gaps. Note that the glue needs to be compatible with the wiring material and the housing material.
    Sealing ring: Install stress release + moisture-proof sealing ring at the outlet of the wiring, which can prevent pulling damage and also prevent moisture from seeping into the wiring along the wiring.
    Common lead-out for upper and lower circuits: Design the leads of the upper and lower circuits to be in the same position and the same width, and glue them together as a whole to eliminate the gaps at the junction of the leads and the circuits on different planes, thereby eliminating the path through which moisture can seep in.

    3. Waterproofing of the key area: Dynamic sealing
    The key area needs to withstand repeated pressing, which is the key difficulty in dynamic sealing.
    Silicone waterproof cap: Cover the top of the key with a silicone rubber key. When pressed, the flexible deformation maintains the seal and can withstand more than 1 million presses. This is the most commonly used solution.
    Double sealing imprint: Design a 0.005-0.020 inch (approximately 0.13-0.5mm) high silicone sealing ring below the button. When pressed, the sealing ring is compressed to form a secure seal, preventing water from accumulating around the button.
    Saucer-shaped cover structure: Design an inclined canopy between the key and the housing to guide water droplets to slide off and avoid accumulation around the key.
    Waterproof film: Add a layer of waterproof film (such as PET substrate + fluorine coating) above the metal spring to block microscopic invasion paths.

    4. Circuit Layer Waterproofing: Internal Protection
    Even if the external sealing is breached, the circuit layer itself must possess certain waterproofing capabilities.
    Insulation Coating: Apply a waterproof insulation coating on the conductive surfaces of the upper and lower circuits (excluding the 10mm area around the contacts and lead-out terminals), so that the conductive lines do not come into direct contact with the pressure-sensitive adhesive layer, thereby improving the insulation resistance reduction caused by the absorption of moisture by the adhesive layer.
    No Through Holes: Do not open through holes within 5mm of the conductors on the upper and lower circuits, or do not open any through holes for the entire circuit component. The interlayer ventilation holes are not connected to the outside to improve the situation where moisture infiltrates and permeates into the circuit interior.
    Sealing Protection: Apply three-in-one anti-wear, anti-corrosion, and anti-salt fog sealant to the PCB solder joints to enhance circuit protection.

    5. Material Selection: Weather Resistance and Compatibility
    Coating: It is recommended to use 250μm PET (polyester film), which has UV protection properties and can prevent hydrolysis reactions from occurring. Avoid using polycarbonate (PC), as the chemical resistance of PET is 10 times better than that of PC.
    Circuit substrate: Use polyimide (PI) instead of conventional PET for extreme temperature environments (-40°C to above +85°C). The heat resistance and dimensional stability of PI are much better than those of PET.
    Sealing adhesive: Select modified silicone adhesive, which can withstand extreme temperatures of -40°C to 125°C and is compatible with PET, PC, and other materials.
    Backsheet: Use anodized aluminum to provide EMI shielding and heat dissipation functions, while enhancing structural strength.

    6. Pressure Balance: Preventing "Breathing Effect"
    When the temperature changes, the air inside the sealed cavity will expand and contract due to heat and cold, resulting in a "breathing effect" that sucks in moisture.
    Pressure Balance Holes: Design tiny ventilation holes on the waterproof base plate or casing, and cover them with a waterproof breathable membrane (such as ePTFE membrane). This membrane allows air to pass through but prevents liquid water from entering.
    Note: The breathable membrane needs to be of IP68 grade to ensure it can still function properly when submerged.

    7. Testing and Verification: Ensure the Design is Effective
    IPX7 Immersion Test: 1-meter water depth, 30 minutes. Electrical performance tests are conducted within 5 minutes after removal.
    IPX6 Intense Spray Test: 100L/min, 3 minutes, simulating high-pressure water gun rinsing.
    Temperature Cycling Test: 500 cycles of -40°C to 85°C, simulating sealing performance under extreme temperature differences.
    Salt Spray Test: 48-hour salt spray exposure, evaluating corrosion resistance.
    Longevity Post-Waterproof Test: First, conduct 1 million key press life tests, then perform the immersion test to verify whether the waterproof performance degrades after long-term use.

    Summary:
    The core of the waterproof structure design is to "block all possible water entry paths", especially the three vulnerable areas: the edges, the outlet of the wiring, and the key press areas.

    Design Points Key Measures Notes
    Edge Sealing 3-5mm double sealing adhesive edge, use 3M VHB Storage of the adhesive tape should be protected from moisture (humidity < 50%), and it should be used up within 24 hours after opening
    Connector Outlet Injection molding or adhesive sealing treatment Perform secondary injection molding, with a fast delivery time
    Button Area Silicone waterproof cap or double-sealed imprinting Silicone button mold, the sample production cycle is approximately 7-10 days
    Circuit Layer Apply insulating coating without opening holes Carbon paste printing factory can provide insulating coating services
    Material Selection PET coating layer, PI substrate (extreme temperature) There are many PET/PI material suppliers, and samples can be obtained quickly
    Pressure Balance Install ePTFE waterproof breathable film Find a professional breathable film supplier