    What are the requirements for the connection of the COM terminal of the membrane switch?

    2026-06-23

    The wiring of the COM terminal (common terminal) of the membrane switch is a crucial part of the entire circuit design. Improper wiring can directly result in the failure of the keys or instability of the system. The core requirements for the COM terminal wiring are as follows: 

    IMG_0219.JPG
    Potential connection requirements

    The COM terminal must be connected to a specific reference potential and cannot be left floating:

    Connect to GND (most common): The COM terminal is grounded, and the trigger terminal is connected to VCC through an upper pull-up resistor. Under normal conditions, the trigger terminal is at a high level. When the key is pressed, the COM terminal and the trigger terminal are connected, and the trigger terminal is pulled low. The MCU detects the low level and determines that the key is pressed.

    Connect to VCC: The COM terminal is connected to the positive pole of the power supply, and the trigger terminal is grounded through a lower pull-down resistor. Under normal conditions, the trigger terminal is at a low level. When the key is pressed, the trigger terminal is pulled high.

    Do not leave open: If the COM terminal is not connected to any potential, when the key is pressed, no potential change can be formed, and the subsequent circuit will never detect an effective signal.

    Wire width and current-carrying requirements

    The COM terminal carries the common current of multiple keys. The wire width design must meet the current-carrying requirements:

    Minimum wire width: The width of the silver paste circuitry should be ≥ 0.3mm, and the minimum spacing should be ≥ 0.3mm (industry standard).

    The COM wire should be thickened: Since the COM wire provides the electrical path for multiple keys simultaneously, it is recommended that the wire width be 20% to 50% thicker than the trigger wire (if the trigger wire is 0.3mm, the COM wire should be designed as 0.4 to 0.5mm). This is to reduce the line resistance and voltage drop.

    Current limitation: The maximum current of each wire of the Membrane Switch should be ≤ 100mA. The total current at the COM terminal is the sum of the currents of all keys that are pressed simultaneously. When designing, it is necessary to ensure that it does not exceed this limit.

    Wire connection requirements in matrix circuits

    In matrix design, the COM terminal usually corresponds to the row line (Row). When wiring, the following points should be noted:

    • Number of row lines ≤ Number of column lines: The principle of matrix design is that the number of row lines (COM) is usually not more than the number of column lines (trigger). This is to reduce the I/O occupation of the MCU. For example, a 4×4 matrix is controlled by 4 COM lines + 4 trigger lines, controlling 16 keys.
    • Fixed scanning direction: The MCU outputs the scan signal in rows and detects the input signal in columns. The COM terminal must be connected to the output pin of the MCU (or grounded), and the trigger terminal must be connected to the input pin of the MCU (with pull-up/pull-down). The two cannot be interchanged.
    • Diode direction: If the matrix integrates anti-jamming diodes, the anode of the diode usually connects to the COM terminal, and the cathode contacts the trigger end. When wiring, it must be ensured that the forward conduction direction of the diode is consistent with the scanning direction. Otherwise, all keys cannot conduct.

    Grounding and Anti-interference Requirements

    The grounding quality at the COM terminal directly affects the stability of the signal and the anti-interference capability:

    • Low-impedance grounding: The impedance of the grounding path at the COM terminal should be as low as possible. It is recommended to use short and wide traces to connect to the PCB ground plane, avoiding the introduction of impedance by long and thin traces.
    • Common ground design: The COM terminal ground of the Membrane Switch should be kept in common ground with the MCU system ground and power ground to avoid potential differences between different ground reference points that may cause incorrect triggering.
    • Single-point grounding: For high-precision applications, it is recommended to adopt a single-point grounding architecture to avoid noise introduced by ground loops.
    • Shielding layer grounding: If the Membrane Switch has an EMI/RFI shielding layer, the shielding layer should also be connected to the ground of the COM terminal through a low-impedance path.

    Contact resistance and voltage drop control

    The line resistance at the COM terminal directly affects the quality of the trigger signal level:

    • Contact resistance: The resistance of the contacts in the closed state is usually 0.5 to 10 Ω.
    • Calculating the line resistance: R = ρ × (L/W), where ρ is the resistance of the silver paste surface (approximately 0.03 Ω/□), L is the length of the line, and W is the width of the line. For example, a 50mm long and 0.5mm wide COM line, the resistance is approximately 3 Ω.
    • Voltage drop verification: At the maximum operating current, the total voltage drop of the COM terminal line should be controlled within 5% of the power supply voltage. For example, in a 5V system, the voltage drop should be <0.25V.

    Practical Operation Precautions

    • Confirm the potential before wiring: Use a multimeter to measure the potential at the expected connection point of the COM terminal. Determine whether it is GND or VCC to avoid incorrect connections.
    • Check the direction of the wiring: When inserting the COM terminal wiring into the connector, the gold finger surfaces must face the contact tabs of the connector. Reversing the direction will cause all COM wires to be disconnected.
    • Control the welding temperature: If welding is required at the COM terminal, the soldering iron temperature should be controlled at 300-350°C. The single-point welding time should not exceed 3 seconds to avoid damaging the silver paste circuit with high temperature.

    Avoid COM wire crossover: During wiring, there should be sufficient spacing (≥0.3mm) between COM wires and between COM wires and trigger wires to prevent poor insulation ink coverage and resulting short circuits.

    Summary: The core requirements for COM terminal wiring are to connect to a specific potential (GND or VCC), increase the line width, achieve low impedance grounding, and ensure the correct scan direction. When designing, it is recommended that the COM line width be ≥ 0.4mm. The grounding path should be as short and wide as possible. In matrix circuits, pay attention to the direction of the diodes being consistent with the scan direction. After wiring is completed, use a multimeter to verify whether the COM terminal potential is correct and whether the trigger terminal potential can flip normally when the button is pressed. This will confirm that the wiring is correct.