What are the standards for the adhesion test of silver paste circuits?
The adhesion test of the silver paste circuits on the membrane switches has clear international and national standards within the industry. The following is the complete test standard system:

Core standard: ASTM F1842 (for membrane switches)
This is the most authoritative adhesion test standard in the membrane switch industry, issued by the American Society for Testing and Materials (ASTM). The current latest version is ASTM F1842-15 (released in 2015).
This standard is based on the general standard ASTM D3359 and has been specifically modified and optimized for the flexible substrates (such as PET, PC) of membrane switches and printed electronic devices.
Scope of Application
Designed specifically for measuring the adhesion of inks and coatings with a thickness of ≤ 125 μm (5 mils) on plastic substrates such as polyester (PET) and polycarbonate (PC)
Suitable for flexible circuit applications such as membrane switches and printed electronic devices
Test method (based on ASTM D3359 Method B)
Marking: Use a special marking tool to draw 10×10 1mm squares on the silver paste printing surface. The cutting depth must penetrate the silver paste layer and reach the substrate surface.
Cleaning: Use a soft-bristled brush to gently brush 5 times along the diagonal direction to remove loose particles.
Applying Tape: Use 3M 600 series tape (or equivalent tape), and smoothly stick it onto the marked area to ensure no bubbles.
Peeling: Peel off the tape at a 180° angle, at a speed of (300±100) mm/min, quickly.
Rating: Observe the silver paste shedding situation within the grid area, and grade and determine according to the standard.
General standard: ASTM D3359 (tape method)
This is the universal international standard for coating adhesion testing, and ASTM F1842 was derived from this standard.
Two testing methods
| Method | Incision form | Applicable coating thickness | Explanation |
| Method A | X-shaped incision (cross-cutting method) | > 125 μm | Suitable for thicker coatings |
| Method B | Cross-cutting Grid (Grid Method) | ≤ 125 μm | Suitable for the silver paste layer of membrane switches |
The thickness of the silver paste film for the membrane switch is usually between 7 and 12 μm. Therefore, Method B (the grid method) must be used.
Rating Criteria (0 - 5B grades)
| Grade | Area of Delamination | Judgment |
| 5B | 0% (The cutting edge is completely smooth with no single piece falling off) | Best adhesion |
| 4B | ≤ 5% (There is a slight detachment at the incision junction.) | Excellent adhesion |
| 3B | 5% - 15% | Good adhesion |
| 2B | 15%~35% | Average adhesion |
| 1B | 35% - 65% | Poor adhesion |
| 0B | > 65% | Extremely poor adhesion |
Chinese national standard: GB/T 9286
This is the paint film grid test standard that China has equivalently adopted from ISO 2409, and it is widely used in domestic enterprises.
Grid spacing: When the film thickness is ≤ 60 μm, the spacing is 1 mm; when the film thickness is 61 - 120 μm, the spacing is 2 mm.
Rating criteria (0 - 5 levels): Level 0 is the best (no detachment), level 5 is the worst (more than 65% detachment)
Correspondence with ASTM D3359: Level 0 of GB ≈ Level 5B of ASTM
Silver paste manufacturer standard: GB/T 17473
The adhesion test for conductive silver paste is conducted in accordance with the standard GB/T 17473, and the test method also employs the 3M 600# tape grid test.
Qualification standard: Usually, a grade 5B (without peeling) is required.
The adhesion index in the specification of silver paste products is generally indicated as "5B (3M 600# tape, hundred-grid test)"
General criteria for the membrane switch industry
Based on the above standards, the actual determination requirements for the adhesion of the silver paste lines on the membrane switch are as follows:
| Item | Standard Requirements | Test Method |
| Bar Test | ≥ 4B grade (peeling ≤ 5%), recommended ≥ 5B grade | ASTM F1842 / GB/T 9286 |
| Tape model | 3M 600 series (or equivalent) | - |
| Grid specification | 10×10, spacing 1mm | - |
| Separation angle | 180° | — |
| Tearing speed | (300 ± 100) mm/min | — |
| Bending test | After being bent repeatedly 5 to 10 times, the resistance increase should be no more than 30% | Industry standard practice |
| Resistant to friction | No peeling occurs after dry/wet friction | Industry standard practice |
Test Precautions
Environmental conditions: The test should be conducted under standard conditions of a temperature of 23 ± 2℃ and a humidity of 50 ± 5%.
Sample status: The silver paste must be fully cured before testing. Test results of samples that are not fully cured are invalid.
Test area: The silver paste solidified area (not the circuit area) should be selected, with an area large enough to accommodate a complete 10×10 grid.
Tool status: The grid-cutting tool must be sharp, with a blade angle of 15 to 30 degrees. Dull tools will result in incomplete cutting and distorted results.
Tape preservation: 3M tape should be stored sealed to avoid loss of adhesive strength and affect the consistency of the test.
Summary: The core standards for the adhesion test of silver paste circuits on membrane switches are ASTM F1842-15 (specific for membrane switches) and ASTM D3359 method B (general grid method), and the corresponding domestic standard is GB/T 9286. The judgment requirement is ≥ 4B grade (peeling ≤ 5%), and high-quality products should reach 5B grade (zero peeling). During the test, 3M 600# tape, 1mm spacing grid, and 180° peel-off are used, and the test is conducted under standard conditions.