What are the temperature resistance test standards for control panel graphics?
The temperature resistance test of the control panel graphics is not a single standard, but a set of standard systems divided according to the application field (such as automobiles, home appliances, industry) and the test purpose (measuring lifespan, measuring deformation, measuring material limits).
To help you make a clearer choice of the suitable standard, I have organized it into three major categories: finished product reliability testing (the most commonly used), material performance testing, and specific industry/material standards.

1. Standard for finished product reliability testing (most commonly used)
This type of standard mainly simulates the environment in which the product is used in practice to verify whether the finished film panel (including ink, glue, and substrate) is qualified.
International Electrotechnical Commission standards (global universal)
IEC 60068-2 series: This is the "bible" for environmental tests of electronic and electrical products.
IEC 60068-2-2 (High Temperature Test): Verify the panel's tolerance in a dry hot environment (e.g., storing at 85°C for 1000 hours).
IEC 60068-2-14 (Temperature Change/Cycle): Verify whether the panel will delaminate, bubble or crack under alternating cold and hot conditions (e.g., -40°C ⇋ 85°C).
IEC 60068-2-78 (Dew Point Test): Also known as the "Double 85 Test" (85°C + 85% humidity), mainly evaluating moisture resistance and anti-aging capabilities.
🇨🇳 Chinese National Standard (GB/T)
Domestic enterprises usually directly reference or adopt equivalent IEC standards:
GB/T 2423 series: Corresponding to IEC 60068 series.
GB/T 2423.2: Environmental testing for electrical and electronic products - Part 2: Test method - Test B: High temperature.
GB/T 2423.3: Test Ca: Constant humidity and heat test.
GB/T 2423.22: Test N: Temperature variation (cold and heat shock).
GB/T 7141-2008: "Plastic thermal aging test methods", used to evaluate the retention rate of performance after long-term thermal aging.
🇺🇸 American Society for Testing and Materials Standard (ASTM)
ASTM D638: Although mainly a tensile test, it is often used to measure the mechanical property attenuation under high temperatures.
ASTM D648: Determination of the plastic load deformation temperature (for the material itself).
2. Material Physical Performance Testing Standards
These standards are mainly used during the material selection stage to test the physical limits of film substrates (such as PET, PC, PI).
| Test items | Common standards | Purpose |
| Thermal deformation temperature | ISO 75 / GB/T 1634 | To determine the temperature at which the material undergoes deformation under pressure (for example, PC usually around 120°C). |
| Vickers softening point | ISO 306 / GB/T 1633 | To determine the temperature at which the material surface is pierced by a standard needle by 1mm (reflecting the heat resistance and softening ability). |
| Thermal expansion coefficient | ASTM E831 / GB/T 1036 | To determine the rate of size change of the material when heated (crucial for precision circuit panels). |
| Thermogravimetric analysis | GB/T 27761 | To determine the temperature at which the material begins to decompose and lose weight (for example, PI usually above 500°C). |
3. Strict standards for specific industries
If your control panel graphics are used in specialized industries, you must follow more stringent industry regulations:
Automotive industry (the strictest)
IEC TS 63126: "Quality Assurance Guidelines for Photovoltaic Modules, Components and Materials in High Temperature Environments". It defines additional test requirements for temperature grades 1 (T98 ≤ 80°C) and 2 (T98 ≤ 90°C).
Corporate standards of Volkswagen, General Motors, Ford, etc.: Usually, panels are required to pass cold and hot shock tests from -40°C to +85°C, and must be resistant to sunscreen and corrosion from sweat.
Key considerations: Not only the appearance is evaluated, but also the changes in the feel of the buttons (force) and color difference (ΔE < 2.0).
Medical and food industries
ISO 10993: If the panel comes into contact with the human body, it is necessary to test the biocompatibility and material stability after high-temperature sterilization (such as ethylene oxide or high-temperature steam)
4. Summary and Recommendations
For ordinary household appliances/indoor equipment:
Refer to GB/T 2423.2, and conduct 85°C / 168-hour constant temperature aging.
For automotive/outdoor equipment:
Must refer to IEC 60068-2-14 to conduct cold and hot shock (-40°C ⇋ 85°C, 500 cycles).
Refer to IEC 60068-2-78 to conduct double 85 tests (1000 hours).
For material research/comparison:
Refer to ISO 75 for measuring heat deformation temperature, and refer to ASTM E831 for measuring heat expansion coefficient.
Tips for avoiding pitfalls: When citing standards, make sure to confirm whether it is for "finished products" or "raw materials". For example, using ISO 75 to measure a finished film panel is inappropriate; that is a standard for measuring plastic particles or samples.