What should I do if the membrane keypad is already stuck?
Once a membrane keypad becomes stuck, handling it requires extreme caution. Because a membrane keypad is a multi-layer structure (panel layer, isolation glue layer, circuit layer), if the internal glue fails or the structure is damaged, irreversible damage can easily occur.
For cases where the switch has already become stuck, it is recommended to follow the steps below for troubleshooting and attempting to repair:

1. Preliminary Diagnosis: Differentiation between "Physical Adhesion" and "Electrical Adhesion"
Physical Adhesion (Hard to the touch/No rebound): After pressing the button, it feels soft and there is no crisp clicking sound. Even when pressed, it doesn't spring back. This indicates that the isolation adhesive layer (Dot Spacer) between the upper and lower layers has collapsed, melted, or stuck together.
Electrical Adhesion (Linked Keys/Serial Keys): Pressing one key triggers several adjacent keys. This is usually due to liquid infiltration, causing internal circuit shorting, or the detachment of conductive silver paste resulting in bridging.
2. Attempt at Repairing "Electrical Adhesion" (Bonding)
If the bonding is caused by liquid infiltration, there is still some value in the rescue attempt:
Complete power-off: Immediately turn off the equipment and disconnect the power supply.
Gentle cleaning: Use high-purity anhydrous alcohol (isopropyl alcohol) or a dedicated electronic contact cleaner, drop it into the gap of the button, repeatedly press the button, utilize the alcohol to dissolve the dirt or sugar inside, and then let it stand and dry completely.
Multimeter verification: After drying, use a multimeter to test the continuity of the button and the adjacent buttons, confirm whether the short circuit has been eliminated.
3. Attempt at Repairing "Physical Adhesion" (No Rebound)
The repair of "physical adhesion" is extremely difficult because once the isolation layer is crushed or melted, it is very hard to restore its original elasticity:
Slight Adhesion (Try Pressing Method): If it is only due to long-term non-use or slight moisture exposure that causes slight stickiness, you can try pressing the button with appropriate force quickly and continuously for several dozen times to attempt to separate the adhered isolation layer.
Severe Adhesion (Not Recommended to Disassemble): If pressing is completely ineffective, it indicates that the internal isolation glue has undergone irreversible deformation. Strongly do not recommend disassembling the upper and lower layers of the membrane keypad by yourself. Because the interlayer of the membrane keypad uses special pressure-sensitive glue, once it is torn open, it is not only extremely difficult to perfectly align and adhere, but also completely destroys the dust-proof and water-proof sealing performance, resulting in the entire keyboard being scrapped.
4. Ultimate Solution: Direct Replacement
Cost and Benefit Assessment: The membrane keypad is a consumable precision component. Its internal structure determines that it can only be replaced but not repaired. The membrane keypad components of the same model on the market usually cost only a few dollars.
Operation Recommendation: If it still sticks or malfunctions after cleaning, the most sensible approach is to directly purchase a brand-new membrane keypad of the same model for a complete replacement. This not only solves the problem completely but also ensures the feel and long-term reliability of the equipment.
Summary: When the membrane keypad is stuck, first try to solve the electrical short circuit problem by cleaning with isopropyl alcohol; if it is caused by the collapse of the physical structure without rebound, do not forcefully disassemble, and directly replacing the new part is the most time-saving and labor-saving choice.